Difference between revisions of "How to measure power consumption"
Matt garman (Talk | contribs) |
|||
Line 1: | Line 1: | ||
+ | ==Direct measurement during operation== | ||
To monitor the laptop's power consumption while it is running, unplug the AC power and run: | To monitor the laptop's power consumption while it is running, unplug the AC power and run: | ||
:{{cmdroot|watch -n1 'cat /proc/acpi/battery/BAT0/*'}} | :{{cmdroot|watch -n1 'cat /proc/acpi/battery/BAT0/*'}} | ||
Line 13: | Line 14: | ||
Note that running on battery power may activate power-saving mechanisms, so unless you take care to deactivate them this does not reflect power consumption under AC power. | Note that running on battery power may activate power-saving mechanisms, so unless you take care to deactivate them this does not reflect power consumption under AC power. | ||
+ | ==Measurement script== | ||
+ | See [[Script_for_monitoring_power_consumption]]. | ||
+ | |||
+ | ==Measurement for synthetic workloads== | ||
+ | Use the [http://bltk.sourceforge.net Battery Life Tool Kit] tool. | ||
+ | |||
+ | ==Measurement during suspend== | ||
To measure power consumption while the laptop is suspended, use the [[ACPI sleep power drain test script]]. | To measure power consumption while the laptop is suspended, use the [[ACPI sleep power drain test script]]. | ||
− | For reducing power consumption, see [[How to reduce power consumption | + | ==See also== |
+ | For reducing power consumption, see [[How to reduce power consumption]]. |
Revision as of 13:58, 8 October 2006
Contents
Direct measurement during operation
To monitor the laptop's power consumption while it is running, unplug the AC power and run:
# watch -n1 'cat /proc/acpi/battery/BAT0/*'
This requires ACPI to be enabled. The value given is (roughly) an averge over the last minute.
Alternatively, load the tp_smapi module and run the following with AC power unplugged:
# watch -n1 'cat /sys/devices/platform/smapi/BAT0/power_now'
or
# watch -n1 'cat /sys/devices/platform/smapi/BAT0/power_avg'
The former provides the instantaneous power draw, and the latter is (roughly) an average over the last minute. It's OK to use tp_smapi's force_discharge function instead of physically disconnecting AC power.
Note that running on battery power may activate power-saving mechanisms, so unless you take care to deactivate them this does not reflect power consumption under AC power.
Measurement script
See Script_for_monitoring_power_consumption.
Measurement for synthetic workloads
Use the Battery Life Tool Kit tool.
Measurement during suspend
To measure power consumption while the laptop is suspended, use the ACPI sleep power drain test script.
See also
For reducing power consumption, see How to reduce power consumption.